putty download

 

 

 

 

Remote Monitoring Unit(RMU)

TYPE

Vision IIIR

Display

 

6 inch monochrome LCD (340x280)

Mist Level Display mode (Bar&Digital Value)

Scanning Time

50msec for each

Max. No of Group

8 Groups

Measuring Range

0 - 5.00 mg/liter

Communication signal

- Input

- Output

 

RS-485 (protocol : Modbus)

RS-485 (protocol : Modbus Dual)

Electrical requirement

Power supply

- Current rating

- Fuse rating

- Over voltage protection

 

24VDC

1.5A

2A

+30% -20% of voltage rating (24V DC)

Temp Rating

0℃to 70℃

Memory

- Event Log

- History Log

- MAX. No. of Detecting Point

 

3000 Data

10 Sec X 3Days

112 Points

ALARM FUNCTION

Alarm & Failure status

Mist Alarm

- Main mist Alarm

- Pre-warning Alarm

- System Fault Alarm

 

 

RMU-Red LED On (Alarm Indicators Panel)

and Alarm channel displayed on LCD

RMU-Yellow LED On (Fan, Communication Alarm Indicators panel) and failed channel displayed on LCD

Alarm Setting

 

Main mist Alarm (Max 2.0mg/liter)

Pre-warning Alarm (User adjustable)

Alarm Contacts

 

Main mist N.O (8ea), Pre-warning Alarm N.C (8ea) - NO, NC selectable 125VAC 0.5A, 30VDC 1.0A, 1a1b

Remote Control



Access your remote HMI from anywhere around the world
Utilizing a 128 bit encrypted VPN tunnel
PC / iPad / Android / Tablet PC / iPhone

Detector Unit

TYPE

VISION IIIA, Multi sensor

Suction System

High quality miniature fan (5VDC 1.0W)

Sensitivity

0.01 mg/Liter (0.01 ppm)

Output Signal



 

Suitable for all lubricating oil types and variations

RS485

 

Junction BoxRs

TYPE

VISION IIIJB

Input/Output

RMU/14detectors on RS485

Power

DC24V

CONSTRUCTION

 

Weight(RMU/JB/Detector)

7.5kg/2.5kg/1.5kg Gross

Housing(RMU, JB/Detector)

Carbon steel, Aluminum/Aluminum

Enclosure

 

IP-44 (RMU/Detector)

IP-56 (J/B)

Dimension (W x H x D)

380 x 250 x 130 (RMIU)

260 x 160 x 90 (JB)

98 x 100 x186 (Detector)